Dx 9100 manual






















The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and mainte-nance instructions in the literature accompanying this unit. Application Specific Controllers—DX Digital Controller, Version 1 3 Installation The DX Digital Controller, Version 1, has field wiring terminals inside the controller enclosure. It is designed for installation inside a control panel or on the controlled equipment via DIN rail. Figure 3: DX on a DIN Rail Extension Modules. Configuration Guides—DX Configuration Guide 7 The DX processes the analog and digital input signals it receives, using twelve multi-purpose programmable function modules, a software implemented Programmable Logic Controller (PLC), time schedule modules, and optimal start/stop modules; producing the required outputsFile Size: 1MB.


2 Technical Bulletins—DX Extended Digital Controller •Optimal Stop Operation 54 •Programmable Function Modules: Control Algorithms 55 •Numeric Calculation Algorithms 72 •Numeric Calculation Algorithms for Version or Later 76 •Other Functions 77 •Programmable Logic Control 82 •Dial-up Feature 89 •Power Up Conditions 90 •Password Feature (Versions , , , or. The DX communicates with the XT via the XT-Bus, and when the DX is connected to an N2 Bus (or Bus 91), data from the XT is available to a Supervisory System. Up to eight XT modules can be connected to the XT-Bus. The DX provides 16 alarm inputs and two relay outputs. Each alarm input and relay output can be matched to a video input. For example, alarm input 5 can match video input 3 and relay 1. You can connect wires from the sensors to the respective alarm inputs on the connectors on the back panel of the DX


2 Application Specific Controllers—DX Digital Controller, Version 2 Features and Benefits (Cont.) Built-in local status display and control panel Optional text and graphic display unit (DT) Optional manual override switches on extension modules Display and override capabilities are available close to the controlled equipment. The DX provides 16 alarm inputs and two relay outputs. Each alarm input and relay output can be matched to a video input. For example, alarm input 5 can match video input 3 and relay 1. You can connect wires from the sensors to the respective alarm inputs on the connectors on the back panel of the DX The DX is a digital control solution for multiple chiller or boiler plant control applications, for the Heating, Ventilating, and Air Conditioning (HVAC) process of Air Handling Units (AHUs) or for distributed lighting and related electrical equipment control applications. It provides precise direct digital control as well as.

0コメント

  • 1000 / 1000